Abstract:
We describe a precise calibration procedure for an Offner imaging hyperspectrometer. We analyze the influence of the calibration on the accuracy of the spectral distribution registration. We conduct a comparative analysis of the experimental data with the results of the precise measurements of spectral distributions made using a high-precision laboratory spectrograph MS7504.

Keywords:
hyperspectrometer, calibration, tuned laser, Earth remote sensing.

Citation:
Podlipnov VV, Skidanov RV. Calibration of an imaging hyperspectrometer. Computer Optics 2017; 41(6): 869-874. DOI: 10.18287/2412-6179-2017-41-6-869-874.

References:

  1. Lee JH, Kang KI, Park JH. A very compact imaging spectrometer for the micro-satellite STSAT3 International Journal of Remote Sensing 2011; 32(14): 3935-3946. DOI: 10.1080/01431161003801328.
  2. Mouroulis P, Sellar RG, Wilson DW, Shea JJ, Green RO. Optical design of a compact imaging spectrometer for planetary mineralogy. Opt Eng 2007; 46(6): 063001. DOI: 10.1117/1.2749499.
  3. Lobb DR. Imaging spectrometer. Patent EP 0961920 B1 of May 12, 2004.
  4. Oskotsky M, Russo MJ Jr. Airborne hyperspectral imaging system. Patent US 7944559 B2 of May 17, 2011.
  5. Prieto-Blanco X, Gonz<lez-Nu>ez H, de la Fuente R. Off-plane anastigmatic imaging in Offner spectrometers. J Opt Soc Am A 2011; 28(11): 2332-2339. DOI: 10.1364/JOSAA.28.002332.
  6. Tennant WE. Graded order-sorting filter for hyperspectral imagers and methods of making the same. Patent US 7936528 B2 of May 3, 2011.
  7. Kazanskii NL, Kharitonov SI, Karsakov AV, Khonina SN Modeling action of a hyperspectrometer based on the Offner scheme within geometric optics  2014; - 38(2): 271-280.
  8. Siliuk OO, Katkovsky LV. Methods and results of image cross-calibration of the Belarusian satellite and other sensors. Current problems in remote sensing of the earth from space 2016; 13(4): 261-270. DOI: 10.21046/2070-7401-2016-13-4-261-270.
  9. Vinogradov AN, Egorov VV, Kalinin AP, Rodionov AI, Rodionov ID. On board visual and near UV-band hyperspectrometr with high spatial resolution. Current problems in remote sensing of the earth from space 2012; 9(3): 101-107.
  10. Vinogradov AN, Egorov VV, Kalinin AP, Rodionov AI, Rodionov ID, Rodionova IP. Design and examination of the near infrared band hyperspectrometer BIK1 [In Russian]. Moscow: SRI RAS; 2017. ISBN: 978-5-00015-015-3.
  11. Karpeev SV, Khonina SN, Kharitonov SI. Study of the diffraction grating on the convex surface as a dispersive element. Computer Optics 2015; 39(2): 211-217. DOI: 10.18287/0134-2452-2015-39-2-211-217.
  12. Karpeev SV, Khonina SN, Murdagulov AR, Petrov MV. Alignment and study of prototypes of the Offner hyperspectrometer [In Russian]. Vestnik of Samara University 2016; 15(1): 197-206. DOI: 10.18287/2412-7329-2016-15-1-197-206.
  13. CMV4000. Source: <http://www.cmosis.com/products/pro­duct_detail/cmv4000>.

© 2009, IPSI RAS
151, Molodogvardeiskaya str., Samara, 443001, Russia; E-mail: journal@computeroptics.ru ; Tel: +7 (846) 242-41-24 (Executive secretary), +7 (846)332-56-22 (Issuing editor), Fax: +7 (846) 332-56-20